Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Working Flow Rate: How to Compare Vacuum Pumps .

Working Flow Rate: How to Compare Vacuum Pumps .

Featured Article Please check out our Diaphragm Vacuum Pump Systems section to find manufacturers that sell these products Diaphragm vacuum pumps with flow paths constructed of fluoropolymers like PTFE (e.g., Teflon ®, DuPont, Wilmington, DE) offer tremendous advantages for laboratories.Compared with the use of traditional oil-sealed rotary vane pumps .

Fundamentals of Vacuum | Hydraulics & Pneumatics

Fundamentals of Vacuum | Hydraulics & Pneumatics

Mechanical vacuum pumps. A conventional vacuum pump may be thought of as a compressor that operates with its intake below atmospheric pressure and the discharge at atmospheric pressure. Compressors and vacuum pumps .

Rules to Follow to Avoid Pump Problems | Valin

Rules to Follow to Avoid Pump Problems | Valin

Aug 05, 2014 · A final note before discussing NPSH. Pressure for centrifugal pumps (inlet and outlet) is measured in Feet of Head and pressure for positive displacement pumps is typically measured in psi. One of the exceptions is for air operated diaphragm (AOD) pumps, which is a positive displacement pump where discharge pressure .

Main affect of vacuum pump discharge pressure - Knowledge .

Main affect of vacuum pump discharge pressure - Knowledge .

And form a vacuum the suction port, that is to say, the discharge pressure is another major factor which affecting the operating efficiency of the liquid ring vacuum pump. The discharge pressure has big impact on the vacuum pump capacity and shaft power consumption. When the vacuum pump system is running, if the discharge pressure .

How to Control Liquid Ring Vacuum Pumps

How to Control Liquid Ring Vacuum Pumps

transmitter, a pressure controller and a recycle valve (typically a pneumatic diaphragm operated globe valve) should be considered. This combination will maintain a constant suction pressure by recycling non-condensables from the separator discharge to the vacuum pump suction. It is a good idea to have a vacuum .

Three ways to improve pump performance| Concrete .

Three ways to improve pump performance| Concrete .

May 22, 2012 · Atmospheric pressure is what enables a pump to lift water. Mother Nature plays an important role by exerting 14.7 psi on any body of water at sea level. This limits the suction head of any pump to 33.9 feet, but only if perfect vacuum occurs in the pump.

How to Size Liquid Ring Vacuum Pumps

How to Size Liquid Ring Vacuum Pumps

The discharge pressure of the pump is needed to determine any reduction of pump capacity or any increase in operating horse-power. Most liquid ring vacuum pumps are designed to operate from a vacuum suction to an atmospheric discharge pressure. If the discharge pressure is increased, then more energy or brake

CL Pump & Compressor Series | NASH Liquid Ring

CL Pump & Compressor Series | NASH Liquid Ring

The NASH CL liquid ring vacuum pump and compressor series delivers classic Nash performance with a broad range of suction volume, vacuum, and pressure. This single stage liquid ring vacuum pump .

How Does Pump Suction Limit the Flow? | Pumps & Systems

How Does Pump Suction Limit the Flow? | Pumps & Systems

Dec 17, 2011 · One of the advantages of centrifugal pumps over positive displacement pumps is an ability to operate with a wide flow range. Since a centrifugal pump operates at the intersection of a pump curve and a system curve, varying the system curve easily changes the pump's operating point (see Figure 1). Figure 1. Flow control of the centrifugal pump by the discharge .

Pumping Condensate from Vented Receivers | Spirax Sarco

Pumping Condensate from Vented Receivers | Spirax Sarco

Vented pumps, pumping traps and pump-trap installations. Discharge lines from pumps vented to atmosphere are sized on the discharge rate of the pump. Condensate passing through pumping traps and pump-trap combinations in closed loop applications will often be at higher pressures and temperatures and flash steam will be formed in the discharge .

Pump Maintenance Know-How Tips for Identifying, Correcting .

Pump Maintenance Know-How Tips for Identifying, Correcting .

If the pump discharge pressure and suction vacuum were measured at start up, the latest readings should be compared to the originally recorded readings. When troubleshooting any pump and system, follow the high abnormal reading. A higher than normal discharge pressure reading will indicate a decrease in suction vacuum.

Centrifugal pump system tips, do's and dont's

Centrifugal pump system tips, do's and dont's

In residential systems, the pressure switch shuts the pump down when the pressure is high which means there is low or no flow. 3. Use pressure gauges. Make sure your pump has a pressure gauge on the discharge side close to the outlet of the pump this will help you diagnose pump .

Rules to Follow to Avoid Pump Problems | Valin

Rules to Follow to Avoid Pump Problems | Valin

Aug 05, 2014 · A final note before discussing NPSH. Pressure for centrifugal pumps (inlet and outlet) is measured in Feet of Head and pressure for positive displacement pumps is typically measured in psi. One of the exceptions is for air operated diaphragm (AOD) pumps, which is a positive displacement pump where discharge pressure is measured in Feet of Head.

Vacuum Pump Oil - HVAC School

Vacuum Pump Oil - HVAC School

Dec 26, 2018 · A seal in a vacuum pump between its high pressure and low pressure, or induction and exhaust sections of the pumping process, specifically for rotary vane pump application allows for separation of gas and oil within the pump reducing any unwanted contamination. . Vapor and Discharge You have oil running into a pump where It is mixed with .

Common Pump Formula - MGNewell

Common Pump Formula - MGNewell

= static discharge head h ft = pressure drop in discharge line p t > 0 for pressure p t < 0 for vacuum p t = 0 for open tank Total Suction Head H s = h s + h fs + (± p s) where: h s = static suction head > 0 for flooded section < 0 for flooded section h fs = pressure drop in suction line p s > 0 for pressure p s < 0 for vacuum p s = 0 for open .

What are the various ways to increase the suction pressure .

What are the various ways to increase the suction pressure .

Jun 11, 2017 · The vacuum is created by vapor pressure of liquid in the system. but it does not restrict it when we use gas. For higher vacuum use we add multiple stages. For reduction of .

How to Operate and Maintain Your Liquid Ring Vacuum Pump .

How to Operate and Maintain Your Liquid Ring Vacuum Pump .

Mar 25, 2020 · Recommended Approach to Liquid Ring Vacuum Pump Maintenance. Liquid-ring vacuum pumps are built for long-lasting, high powered performances and can generally withstand a range of pressure levels. That said, a vacuum pump .

Vacuum Pump - an overview | ScienceDirect Topics

Vacuum Pump - an overview | ScienceDirect Topics

This paper presents oil flooded screw vacuum pumps with a patented flexible discharge port. Such a screw vacuum pump has its volume ratio or discharge port matched with the real pressure ratio. The most under-compression and over-compression are eliminated, and the vacuum pump .

Vacuum System Troubleshooting

Vacuum System Troubleshooting

performance of the vacuum pump. Then compare the measured vacuum to the manufacturer's published ultimate vacuum value. If this value is reasonably close to the published value this is an indication that there is an issue with the vacuum system in the form of leaks or outgassing. 3. Excessive pump discharge or back pressure – Vacuum pumps

Pump Head vs Discharge Pressure (Easy explanation and .

Pump Head vs Discharge Pressure (Easy explanation and .

Aug 10, 2017 · The pressure at the discharge of the pump, however, will be higher for the heavier solution. That's why we would not be able to do simply looking at a pressure gauge and figure out what is pump's discharge head ability is. Hopefully this post reveal some light on the difference between head and pressure.

TUTORIAL CENTRIFUGAL PUMP SYSTEMS

TUTORIAL CENTRIFUGAL PUMP SYSTEMS

If we apply this idea to the pump system of Figure 5, even though the discharge pipe end is open, it is possible to have pressure at the pump discharge because there is sufficient friction in the system and elevation difference.

Education Safety - Welcome to Gorman-Rupp Pumps

Education Safety - Welcome to Gorman-Rupp Pumps

If the pump discharge pressure and suction vacuum were measured at start up, the latest readings should be compared to the originally recorded readings. When troubleshooting any pump and system, follow the high abnormal reading taken earlier. A higher than normal discharge pressure reading will indicate a decrease in suction vacuum.

Pump Selection Handbook - Multiquip Inc

Pump Selection Handbook - Multiquip Inc

partial vacuum and discharge pressure necessary to move water through the casing. The impeller and volute form the heart of a pump and help determine its flow, pressure and solid handling capability. An impeller is a rotating disk with a set of vanes coupled to the engine/motor shaft that produces centrifugal force within the pump .

Theoretical Model for the Performance of Liquid Ring Pump .

Theoretical Model for the Performance of Liquid Ring Pump .

In the discharge process (Curves 3-4), the discharge pressure keeps constant and all the gas is discharged from the pump. The corresponding zones in a liquid ring pump are divided into the suction zone (Sector DOA ), the compression zone (Sector AOB ), and the discharge .

Pump Maintenance Know-How Tips for Identifying, Correcting .

Pump Maintenance Know-How Tips for Identifying, Correcting .

If the pump discharge pressure and suction vacuum were measured at start up, the latest readings should be compared to the originally recorded readings. When troubleshooting any pump and system, follow the high abnormal reading. A higher than normal discharge pressure reading will indicate a decrease in suction vacuum, and could be a sign of a .

Methods for Diaphragm Pump Selection - Air Dimensions, Inc.

Methods for Diaphragm Pump Selection - Air Dimensions, Inc.

When the pump inlet pressure exceeds 0 PSIG, the pump performance capabilities (in terms of discharge pressure and flow rate) can increase significantly. It is very important that under these circumstances specific calculations are done by ADI to avoid oversizing the pump.

Centrifugal Pumps - Engineering ToolBox

Centrifugal Pumps - Engineering ToolBox

p 1 = pressure at inlet (N/m 2) ρ = density (kg/m 3) g = acceleration of gravity (9.81) m/s 2. v 2 = velocity at the outlet (m/s) Head described in simple terms. a pump's vertical discharge "pressure-head" is the vertical lift in height - usually measured in feet or m of water - at which a pump can no longer exert enough pressure to move water.

Vacuum Pump Discharge & Air / Oil Separation

Vacuum Pump Discharge & Air / Oil Separation

Vacuum Pump Discharge & Air / Oil Separation. Oil mist exhaust filters capture oil fog, mist or smoke from the discharge of vacuum pumps. The EE and EF series designed for laboratory and medical vacuum pumps, these compact oil mist eliminators offer the option of a back pressure .

What is Pump Cavitation and How Do I Avoid It?

What is Pump Cavitation and How Do I Avoid It?

When a pump is under low pressure or high vacuum conditions, suction cavitation occurs. If the pump is "starved" or is not receiving enough flow, bubbles or cavities will form at the eye of the impeller. As the bubbles carry over to the discharge side of the pump, the fluid conditions change, compressing the bubble into liquid and causing it to .

Positive Displacement Pumps - an overview | ScienceDirect .

Positive Displacement Pumps - an overview | ScienceDirect .

All rotary pumps use some form of rotating element, such as gears, vanes, or lobes to increase the discharge pressure. Reciprocating pumps use pistons or wobble plates to increase the pressure. Rotary Locations of measurement points for rotary positive-displacement pumps should be based on the same logic as in-line centrifugal pumps.