Set Up Instructions 9. While the pump is running, add enough vacuum pump oil so that the oil level is even with the line on the reservoir's sight glass. 10. Press 1 or SHIFT/RESET to stop the pump. 11. Replace the black plastic plug on the oil fill port. 12. Replace the access door on the front of the unit.
Robinair VacuMaster vacuum pumps features a two stage design, cleaning the system more thoroughly with a second vacuum, and leading to a deeper ultimate vacuum level. Designed for quick oil changes, the oil fill port and drain plug are easily accessible for fast and complete oil changes, and the easy view sight glass enables users to quickly .
RobinAir Vacuum Pump- Model 15001 You are bidding on a Robinair vacuum pump model 15001 ser. DD- this unit is fully functional and in very good condition. You can return if not fully satisfied! We are happy to accept Paypal. And we are authorized to take Visa and Mastercard over the phone as well. Our shipping rates are based upon weight and size.
No manual valves; Powerful Dual Stage Vacuum pump (170 l/min) PAG and POE oil injection system automatic; UV dye injection system automatic; Large refrigerant tank (20 kg) Automatic purge of Non - condensable gas; Charge with automatic compensation of service hoses; Multi-phase refrigerant recycling during vacuum phase; Accessible vacuum pump .
PREPARING THE VACUUM PUMP The VacuMaster® vacuum pump is shipped without oil in the reservoir. Before starting the station, you must fill the pump with oil and remove the exhaust plug from the end of the pump's handle. Note: The Iso-ValveTM isolation valve on the side of the pump .
Robinair vacuum pumps flyer - US and International pumps Operating Instructions - English (Document # 556679) Operating Instructions - Spanish (Document # 556679)
Jun 20, 2019 · Before you use your vacuum pump, make sure it is full of clean vacuum pump oil. Unscrew the oil fill cap, typically located on the top of the pump, and look on the interior edge of the opening for the fill line. Fill the opening with oil until it reaches that line. Then, replace the oil fill cap. Be sure to only use oil meant for vacuum pumps.
CAutION: Before connecting your vacuum pump to an A/C-R system, remove refrigerant from the system in an accepted manner. Damage to the pump may occur if evacuation is started while the system is under high pressure. Robinair recommends the use of its Refrigerant Recovery and Recycling equipment. 2 to shut down the pump after use. 1.
Robinair's No 15600 CoolTech 2-stage rotary vane design vacuum pump features a 6 CFM free air displacement along with the power and capacity needed for a wide range of service applications. This high-performance unit includes a heavy duty, 1/2 HP, 115V/60Hz thermally protected motor that delivers high torque for easy startup and efficient .
Need Manual readers have rated Robinair SPX 15150 15151 15155 15203 15300 15301 15355 15500 15501 15505 15800 SPX Vacuum Pump Owners Manual 4.0 out of 5.0 based on 2 .
53 receptacle, vacuum pump 1 ra19047 54 washer, #8 ext. tooth 2 11388 55 screw, 8-32 x 1/4" lg 2 110382 56 washer, 1/2" int. tooth 3 110646 57 cap, oil inject bottle 1 ra19914 58 washer, .625 int. tooth 1 523175 59 decal, circuit breaker 1 123708 60 power cord 1 122770 64 strap, velcro 1.5" x 45" 1 121925 65 edge trim, rubber (sold by ft) 1 122708
relieve any vacuum inside the pump. 5. Cap the inlet port to prevent any contamination or loose particles from entering the port. To maintain your high vacuum pump. For maximum performance, Robinair recommends changing vacuum pump oil after each use. Vacuum pump oil. The condition and type of oil used in any high . vacuum pump are extremely .
Robinair 15101 Manual :: View topic - Robinair 15101A vacuum pump Robinair High Vacuum Pump Model #15101B. Specifications: 5CFM Free Air Displacement. : robinair (15600) cooltech vacuum pump The Robinair 15600 CoolTech vacuum pump features power and capacity for a wide range of service
When the vacuum pump countdown reaches zero, the vacuum pump will stop and the unit display will change to the recover function. 9. Replace the plastic plug in the oil fill port. After adding oil to the vacuum pump, add refrigerant to the internal storage vessel. Refer to the instructions on the next page.
View and Download Robinair Model 15401 instruction manual online.
Invent with Robinair; Supplier Portal; Tech4Techs Forum; Catalogs; . Literature & Manuals; Become a Service Center; Invent with Robinair; Supplier Portal; Tech4Techs Forum; Literature & Manuals You are here. Search . Product Part Number Documents ; RA15121A - 236 l/min (10 CFM) Vacuum pump: RA15121A : Attachment Size; user_manual_15400_15600 .
It could be a manual valve or electric solenoid valve that opens to the port that connects to the recovery tank. The line should be open. . Robinair 13204 Premium High Vacuum Pump Oil - 4 Gallons-1 Questions. Robinair 34288 Cool-Tech R-134A Recovery Recycling and.-2 Questions. Top Robinair .
5604052PACK - Vacuum Pump Oil (12 bottles, 600 ml) ACT550-SFK - Flushing Kit for ACxxxPRO A/C Service Unit Series ACM3139 - Complete A/C Database for ACM3000 A/C Service Unit
Theondition c and type of oil used in any high vacuum pump are extremely important in determining the ultimate attainable vacuum. Robinair recommends the use of our Premium High Vacuum Pump Oil. This oil has been specifically blended to maintain maximum viscosity at normal running temperatures and to improve cold weather starts.
These safety messages cover situations Robinair is aware of. Robinair cannot know, evaluate, or advise as to . read this manual, operating instructions and safety precautions must be read and discussed in the operator's . 6 Vacuum Pump Oil Sight Glass 7 Vacuum Pump .
Invent with Robinair; Supplier Portal; Tech4Techs Forum; Catalogs; . Literature & Manuals; Become a Service Center; Invent with Robinair; Supplier Portal; Tech4Techs Forum; Literature & Manuals You are here. Search . Product Part Number Documents ; RA15121A - 236 l/min (10 CFM) Vacuum pump: RA15121A : Attachment Size; user_manual_15400_15600 .
These safety messages cover situations Robinair is aware of. Robinair cannot know, evaluate, or advise as to . read this manual, operating instructions and safety precautions must be read and discussed in the operator's . 6 Vacuum Pump Oil Sight Glass 7 Vacuum Pump .
Bosch Automotive Service Solutions 28635 Mound Road, Warren, MI 48092 USA. Customer Service: 1-800-533-6127 Tech Service: 1-800-533-6127 Email: [email protected]
NOTE: Robinair recommends the use of a thermistor vacuum gauge to most accurately measure vacuum levels. Your pump is now ready to evacuate air conditioning and refrigeration systems. Follow normal service procedures and the A/C-R manufac-turer's instructions for connections to the system. CAUTION Before connecting your vacuum pump to an A/C .
Find helpful customer reviews and review ratings for Robinair 18192 R-134A Manual Replacement Coupler Set . couplers I have. Cry once buy Once. These fit tight don't damage valves (when used carefully) and don't leak. I have a Robinair vacuum pump I paid allot for 20+ years ago, and it still works great. . Manual quick connect couplers .
ROBINAIR 18192 R-134A MANUAL REPLACEMENT COUPLERS Our Price: 76.64 . R-134A LOW SIDE FIELD SERVICE COUPLER, COMPACT DESIGN, BLUE ACTUATOR . ROBINAIR 539471 VACUUM PUMP, STATION 115V 3CFM 34700Z Our Price: 475.00 . ISV, INTERNAL VACUUM PUMP.
3. The pump is shipped without oil in the reservoir. Before starting the pump, fill it with oil. a. 15115: Remove the exhaust FittiNg, and add oil until oil appears in the bottom of the sight glass. Wikipedia's page for SPX Robinair Company Web Site: .
Robinair's No 15400 CoolTech 2-stage rotary vane design vacuum pump features a 4 CFM free air displacement along with the power and capacity needed for a wide range of service applications. This .
15601: Robinair 15601 High Performance CoolTech Vacuum Pump, 6 CFM, 1/3 hp, 13.5 oz. Oil Capacity, 110-115V/220-250V 50/60 Hz
ROBINAIR.COM 800.533.6127 Recover, Recycle, Recharge Machine for R-134a A/C Systems Original Instructions Model: 34288NI Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com